L1/TJ-50 | IG Lintels

L1/TJ-50

For standard loading conditions in 50mm wide thin joint cavity wall construction. To achieve loading figures lintels must be built in as shown with firmly butted perpendicular joints.

 

SKU: TJK50 Categories: ,

Description

L1/TJ-50: For Cavity widths 50-65mm

Length
(mm)
Specification Height
(mm)
Thickness
(mm)
Total UDL kN
Intneral Leaf
Total UDL kN
Extneral Leaf
600
1500
A 130 5.0 10 3
1650
1800
B 160 5.0 15 5
1950
2100
C 228 3.2 18 8
2550
2700
D 228 5.0 27 9
2850
3000
E 228 5.0 25 10