The blockwork is built tight against inner face of the steel lintel. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.

Damp Proofing

Provide a damp prood course over all lintels.
For more guidance please contact our technical team here.

 

SKU: L1/HD110 Categories: ,

Description

For Cavity widths 110-125mm

Length (mm) Height
(mm)
Thickness
(mm)
Total UDL
kN 3:1
Total UDL
kN 19:1
600
1500
125 2.9 30 20
1650
2100
145 2.9 30 22
2250
3000
195 3.2 35 30
3150
3600
195 3.2 32 28
3750
4000
195 3.2 30 26