L1/HD 130 WIL

The blockwork is built tight against inner face of the steel lintel. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.

 

SKU: HDK130WIL Categories: ,

Description

For Cavity widths 130-145mm

Length (mm) Height (mm) Thickness (mm) Total UDL kN 3:1 Total UDL kN 19:1
600
1350
115 2.9 20 17
1500
1800
155 2.9 30 25
1950
2100
190 2.9 30 25
2250
2700
212 3.2 36 32