L1/HD 50 215 WIL

The blockwork is built tight against inner face of the steel lintel. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.

 

SKU: HDK50WIL215 Categories: ,

Description

For Cavity widths 50-65mm

Length (mm) Height (mm) Thickness (mm) Total UDL kN 3:1 Total UDL kN 19:1 Fin Height
600
1500
146 2.5 40 35 175
1650
1800
171 2.5 45 40 225
1950
2100
209 2.9 50 45 225