L1/HD 75

The blockwork is built tight against inner face of the steel lintel. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.

Damp Proofing

Provide a damp prood course over all lintels.
For more guidance please contact our technical team here.

 

SKU: L1/HD75 Categories: ,

Description

For Cavity widths 70-85mm

Length (mm) Height
(mm)
Thickness
(mm)
Total UDL
kN 3:1
Total UDL
kN 19:1
600
1200
103 2.9 30 22
1350
1500
117 2.9 30 22
1650
2100
167 2.9 40 35
2250
2550
205 2.9 40 35
2700
3000
205 3.2 40 35
3150
3600
205 3.2 35 32
3750
4200
205 3.2 33 28