L1/S 130 215 WOL

The blockwork is built tight against inner face of the steel lintel. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.

 

SKU: SK130WOL215 Categories: ,

Description

For Cavity widths 130-145mm

Length (mm) Height

(mm)
Thickness
(mm)
Total UDL
kN 3:1
Total UDL kN 19:1 Fin Height
600
1500
120 2.9 30 20 120
1650
2100
155 2.9 30 22 175
2250
2550
190 2.9 35 30 225
2700
3000
190 3.2 35 30 225
3150
3600
190 3.2 32 25 225