L1/S 150 215 WOL

The blockwork is built tight against inner face of the steel lintel. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.

 

SKU: SK150WOL215 Categories: ,

Description

For Cavity widths 150-165mm

Length (mm) Height (mm) Thickness (mm) Total UDL kN 3:1 Total UDL kN 19:1 Fin Height
600
1500
118 2.9 30 20 120
1650
2100
160 2.9 30 22 175
2250
2550
180 2.9 35 30 225
2700
3000
180 3.2 35 30 225
3150
3600
180 3.2 30 25 225