L1/XHD 130

Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.

Damp Proofing

Provide a damp prood course over all lintels.
For more guidance please contact our technical team here.

SKU: L1/XHD130 Categories: ,

Description

For Cavity widths 130-145mm

Length (mm) Height
(mm)
Thickness
(mm)
Total UDL
kN 3:1
Total UDL
kN 19:1
600
1500
155 3.2 45 40
1650
1800
155 3.2 45 40
1950
2100
212 3.2 50 40